Product Description
Characteristic, Uses:
1) cold, hot water supply public building facilities.
2) transport all kinds of corrosive liquid.
3) drinking water production system, such as pure water and mineral water supply pipeline.
4) air conditioning pipe.
5) compressed natural gas pipeline.
6) swimming pool pipe.
7) solar facilities.
8) farming and gardening production transportation system.
9) we can supply different colors of products, according to customer requirements.
10) raw material can change all kinds of plastic, such as PP, PPR, PVC, etc.
Our pipes and fittings can be made, according and conforming to the following international
Standards:
1) American standard (ASTM Sch 40 & Sch 80, SDR 21, SDR 26, SDR41)
2) British standard (BS 3505, BS 5255, 4515)
3) Singaporean standard (SS 141, SS 272, SS 213)
4) Australian standard (AS 1477, AS 1415)
5) Japanese standard (JIS K 6742, JIS K 6741, JIS K 6743, JIS K 6739)
6) National standard (GB 10002, GB 5836, GB 14823, GB 13664)
7) International standard (ISO 4422, ISO 3633, IEC 614, GY 3050)
Characteristic, Uses:
1) cold, hot water supply public building facilities.
2) transport all kinds of corrosive liquid.
3) drinking water production system, such as pure water and mineral water supply pipeline.
4) air conditioning pipe.
5) compressed natural gas pipeline.
6) swimming pool pipe.
7) solar facilities.
8) farming and gardening production transportation system.
9) we can supply different colors of products, according to customer requirements.
10) raw material can change all kinds of plastic, such as PP, PPR, PVC, etc.
Our pipes and fittings can be made, according and conforming to the following international
Standards:
1) American standard (ASTM Sch 40 & Sch 80, SDR 21, SDR 26, SDR41)
2) British standard (BS 3505, BS 5255, 4515)
3) Singaporean standard (SS 141, SS 272, SS 213)
4) Australian standard (AS 1477, AS 1415)
5) Japanese standard (JIS K 6742, JIS K 6741, JIS K 6743, JIS K 6739)
6) National standard (GB 10002, GB 5836, GB 14823, GB 13664)
7) International standard (ISO 4422, ISO 3633, IEC 614, GY 3050)
nominal outside diameter dn | S series SDR series and nominal pressure | ||||||
S16 | S12.5 | S10 | S8 | S6.3 | S5 | S4 | |
SDR33 | SDR26 | SDR21 | SDR17 | SDR13.6 | SDR11 | SDR9 | |
PN0.63 | PN0.8 | PN1.0 | PN1.25 | PN1.6 | PN2.0 | PN2.5 | |
nominal wall thickness en | |||||||
20 | - | - | - | - | - | 2.0 | 2.3 |
25 | - | - | - | - | 2.0 | 2.3 | 2.8 |
32 | - | - | - | 2.0 | 2.4 | 2.9 | 3.6 |
40 | - | - | 2.0 | 2.4 | 3.0 | 3.7 | 4.5 |
50 | - | 2.0 | 2.4 | 3.0 | 3.7 | 4.6 | 5.6 |
63 | 2.0 | 2.5 | 3.0 | 3.8 | 4.7 | 5.8 | 7.1 |
75 | 2.3 | 2.9 | 3.6 | 4.5 | 5.6 | 6.9 | 8.4 |
90 | 2.8 | 3.5 | 4.3 | 5.4 | 6.7 | 8.2 | 10.1 |
110 | 2.7 | 3.4 | 4.2 | 5.3 | 6.6 | 8.1 | 10.0 |
125 | 3.1 | 3.9 | 4.8 | 6.0 | 7.4 | 9.2 | 11.4 |
140 | 3.5 | 4.3 | 5.4 | 6.7 | 8.3 | 10.3 | 12.7 |
160 | 4.0 | 4.9 | 6.2 | 7.7 | 9.5 | 11.8 | 14.6 |
180 | 4.4 | 5.5 | 6.9 | 8.6 | 10.7 | 13.3 | 16.4 |
200 | 4.9 | 6.2 | 7.7 | 9.6 | 11.9 | 14.7 | 18.2 |
225 | 5.5 | 6.9 | 8.6 | 10.8 | 13.4 | 16.6 | - |
250 | 6.2 | 7.7 | 9.6 | 11.9 | 14.8 | 18.4 | - |
280 | 6.9 | 8.6 | 10.7 | 13.4 | 16.6 | 20.6 | - |
315 | 7.7 | 9.7 | 12.1 | 15.0 | 18.7 | 23.2 | - |
355 | 8.7 | 10.9 | 13.6 | 16.9 | 21.1 | 26.1 | - |
400 | 9.8 | 12.3 | 15.3 | 19.1 | 23.7 | 29.4 | - |
450 | 11.0 | 13.8 | 17.2 | 21.5 | 26.7 | 33.1 | - |
500 | 12.3 | 15.3 | 19.1 | 23.9 | 29.7 | 36.8 | - |
560 | 13.7 | 17.2 | 21.4 | 26.7 | - | - | - |
630 | 15.4 | 19.3 | 24.1 | 30.0 | - | - | - |
710 | 17.4 | 21.8 | 27.2 | - | - | - | - |
800 | 19.6 | 24.5 | 30.6 | - | - | - | - |
900 | 22.0 | 27.6 | - | - | - | - | - |
1000 | 24.5 | 30.6 | - | - | - | - | - |
Note:Nominal wall thickness en will be subject to design stress σS12.5MPa |